Product Features
Product Details
Scope of application:It is used to test the moisture permeability of various coated fabrics, composite fabrics, composite films and other materials.
Applicable standards:GB/T12704;ASTM E96;JISL1099;BS 7209。
Technical indicators:
1.Adjustable temperature control accuracy:20~50 ℃ ± 0.1 ℃;
2. Adjustable humidity relative humidity: 40 ~ 95% ±1% RH
3. Standard test temperature and humidity: 23 ℃ ± 0.5 ℃(water temperature)30℃±2℃(air temperature);(potassium acetate method test conditions)20 ℃ ± 0.5 ℃50%±2% RH;20℃±0.5℃ 65%±2% RH;38℃±0.5℃ 50%±2% RH;38℃±0.5℃ 90%±2% RH;40℃ ± 0.5 ℃50%±2% RH;40℃±0.5℃ 90%±2% RH;
4. Wind speed range: 0.02~0.8m/s;
5. Wind speed adjustment mode: touch screen menu manual adjustment;
6. permeable cup holder layer:single layerPotassium acetate;
7. Moisture-permeable cup quantity:9; (national standard, American standard, British standard selection);
8. Number of potassium acetate test cups: 6;
9. Number of potassium acetate sample racks: 6;
10. through the moisture cup holder rotation speed:5rpm/min;
11. ElectricitySource: AC220V ± 10%;
12.WorkRate: 4KW;
13. Overall dimension:700 × 880 × 1760mm;
14. NetWeight: 320Kg.
Instrument features:
1.The refrigeration system adopts the French Taikang refrigeration unit to ensure the stable operation of the whole machine for a long time;
2.The temperature and humidity sensor imported from Switzerland is adopted to ensure the accuracy of the temperature and humidity in the experimental cabin;
3.Using industrial color touch screen operation, Chinese and English menu display;
4.The instrument adopts automatic water function, which is convenient for testing and suitable for long-term testing.
5.The temperature and humidity recorded once per minute can be queried in real time, and can be connected to the printer to print out;
6.Two layers of sample placing rack, each layer9 test cups, greatly increasing the number of samples in a single test, reducing the user's operating costs and improving efficiency;
7.The sample cup is respectively provided with small doors, which reduces the influence on the test environment after the sample is taken for a period of time and after the door is opened, and shortens the re-stabilization time; (fully in lineGB/T12704 ~ 2009 5.1.1 each time after closing the test compartment, must be balanced again within 3 minutes);
8. The turntable sample placement rack is more uniform than the fixed sample rack.